VPD (vapour pressure deficit) is how hard the air pulls water out of your leaves, measured in kPa. Aim for 0.4 to 0.8 kPa for seedlings and cuttings, 0.8 to 1.2 in veg and 1.2 to 1.6 in late flower.
Enter the air temperature and humidity at canopy height. The calculator works out leaf VPD, shows which band it falls in and tells you which way to move. The same targets are in our VPD guide.
Leaf VPD
Leaves usually sit a little cooler than the air because they cool themselves as they transpire. Under LED they often run close to air temperature, as LEDs send less heat to the leaf than HPS. Leave the offset at 2, or measure your top leaves with an infrared thermometer and enter the gap.

Leaves curling or tips burning? VPD problems look a lot like feeding problems. PlantMDx helps you tell them apart. Free, no signup.

VPD chart
Air temperature 18 to 32°C down the side, relative humidity 40 to 85% across the top. Each cell is leaf VPD in kPa with the leaf 2°C cooler than the air. Change the offset in the calculator and the chart follows. On a phone, swipe the chart sideways.
- Too low below 0.4 kPa
- Propagation 0.4 to 0.8 kPa
- Veg 0.8 to 1.2 kPa
- Flower 1.2 to 1.6 kPa
- Too high above 1.6 kPa
| Air °C | 40% | 45% | 50% | 55% | 60% | 65% | 70% | 75% | 80% | 85% |
|---|---|---|---|---|---|---|---|---|---|---|
| 18°C | 0.99 veg | 0.89 veg | 0.79 propagation | 0.68 propagation | 0.58 propagation | 0.48 propagation | 0.37 too low | 0.27 too low | 0.17 too low | 0.06 too low |
| 19°C | 1.06 veg | 0.95 veg | 0.84 veg | 0.73 propagation | 0.62 propagation | 0.51 propagation | 0.40 propagation | 0.29 too low | 0.18 too low | 0.07 too low |
| 20°C | 1.13 veg | 1.01 veg | 0.89 veg | 0.78 propagation | 0.66 propagation | 0.54 propagation | 0.43 propagation | 0.31 too low | 0.19 too low | 0.08 too low |
| 21°C | 1.20 flower | 1.08 veg | 0.95 veg | 0.83 veg | 0.71 propagation | 0.58 propagation | 0.46 propagation | 0.33 too low | 0.21 too low | 0.08 too low |
| 22°C | 1.28 flower | 1.15 veg | 1.02 veg | 0.88 veg | 0.75 propagation | 0.62 propagation | 0.49 propagation | 0.36 too low | 0.22 too low | 0.09 too low |
| 23°C | 1.36 flower | 1.22 flower | 1.08 veg | 0.94 veg | 0.80 veg | 0.66 propagation | 0.52 propagation | 0.38 too low | 0.24 too low | 0.10 too low |
| 24°C | 1.45 flower | 1.30 flower | 1.15 veg | 1.00 veg | 0.85 veg | 0.70 propagation | 0.56 propagation | 0.41 propagation | 0.26 too low | 0.11 too low |
| 25°C | 1.54 flower | 1.38 flower | 1.23 flower | 1.07 veg | 0.91 veg | 0.75 propagation | 0.59 propagation | 0.43 propagation | 0.28 too low | 0.12 too low |
| 26°C | 1.64 too high | 1.47 flower | 1.30 flower | 1.14 veg | 0.97 veg | 0.80 veg | 0.63 propagation | 0.46 propagation | 0.29 too low | 0.13 too low |
| 27°C | 1.74 too high | 1.56 flower | 1.39 flower | 1.21 flower | 1.03 veg | 0.85 veg | 0.67 propagation | 0.49 propagation | 0.32 too low | 0.14 too low |
| 28°C | 1.85 too high | 1.66 too high | 1.47 flower | 1.28 flower | 1.09 veg | 0.90 veg | 0.72 propagation | 0.53 propagation | 0.34 too low | 0.15 too low |
| 29°C | 1.96 too high | 1.76 too high | 1.56 flower | 1.36 flower | 1.16 veg | 0.96 veg | 0.76 propagation | 0.56 propagation | 0.36 too low | 0.16 too low |
| 30°C | 2.08 too high | 1.87 too high | 1.66 too high | 1.45 flower | 1.23 flower | 1.02 veg | 0.81 veg | 0.60 propagation | 0.39 too low | 0.17 too low |
| 31°C | 2.21 too high | 1.98 too high | 1.76 too high | 1.53 flower | 1.31 flower | 1.09 veg | 0.86 veg | 0.64 propagation | 0.41 propagation | 0.19 too low |
| 32°C | 2.34 too high | 2.10 too high | 1.87 too high | 1.63 too high | 1.39 flower | 1.15 veg | 0.91 veg | 0.68 propagation | 0.44 propagation | 0.20 too low |
How to use it
- Put your thermometer and hygrometer at canopy height, not on the tent pole up near the light, and give the reading a few minutes to settle with the lights on.
- Type the air temperature and relative humidity into the calculator.
- Leave the leaf offset at 2°C, or enter what you measure with an infrared thermometer pointed at the top leaves.
- Pick a growth stage to get a target and one change to make. Change one thing at a time, wait an hour, then check again.
- Check again soon after lights off, when humidity usually jumps.
Common questions
What VPD should seedlings and cuttings have?
Keep seedlings and cuttings at 0.4 to 0.8 kPa. Young plants have small root systems and can't replace water quickly, so keep humidity high and temperatures moderate until roots are established.
What VPD should I run in veg and flower?
Run 0.8 to 1.2 kPa through vegetative growth. In early to mid flower aim for 1.0 to 1.5 kPa, then 1.2 to 1.6 kPa in late flower and ripening, where the drier air helps keep moisture off flowers and fruit.
Why does the calculator use leaf temperature?
Transpiration is driven by the gap between the saturated air inside the leaf and the air around it, and the inside of the leaf sits at leaf temperature. A leaf that is cooler than the air gives a lower VPD than an air reading alone shows. If you have an infrared thermometer, measure a few top leaves and enter the difference.
Do leaves under LED run cooler than the air?
Usually only a little. LEDs send less heat to the leaf than HPS, and a well watered leaf cools itself by transpiring. Utah State University research found leaves under LED, HPS and sunlight typically stayed within 2°C of air temperature. Start with an offset of 2°C, and use 1 or 0 if your leaf readings sit close to the air.
How do I raise or lower VPD?
To lower VPD, raise humidity or bring the temperature down: slow the extraction fan on its speed controller so the tent holds more moisture, or add a humidifier. To raise VPD, lower humidity or warm the tent a little: speed up extraction, or run a dehumidifier when the room air is humid too.
Does VPD matter with the lights off?
Yes. When the lights go off the temperature drops and humidity climbs, so VPD falls. Run extraction at its minimum speed overnight rather than off, and watch for condensation on the tent walls.
How it’s worked out: saturation vapour pressure uses the Tetens formula, es(T) = 0.6108 × exp(17.27 × T ÷ (T + 237.3)) kPa, with T in °C. Leaf VPD = es(leaf temperature) minus (RH ÷ 100) × es(air temperature), where leaf temperature is air temperature minus the offset. Air VPD is the same sum with no offset.
25°C, 60% RH, leaf 2°C cooler: es(23) 2.810 minus 0.60 × es(25) 3.168 = 0.91 kPa
The bands follow the stage targets in our VPD guide: propagation 0.4 to 0.8 kPa, vegetative 0.8 to 1.2, early to mid flower 1.0 to 1.5, and late flower 1.2 to 1.6. The chart colours flower from 1.2 so each cell has one colour. For what happens after lights off, see why nutrients stop working at night.
Sources: Michigan State University Extension, Water and VPD; Nelson and Bugbee (2015), Utah State University, leaf temperature under LED, HPS and sunlight.